AK5-50M Accelerometer

Specifications AK5-50M

Parameter

Real Measurement

Measurement range, g

50

Bias repeatability on operational temp, mg (3 sigma)

0.4

One-year composite repeatability, µg

400

Temperature sensitivity , µg/ °C

45

Scale factor, mA/g

0.32

One-year composite repeatability, ppm

390

Temperature sensitivity, ppm/ °C

270

Axis misalignment, (-rad)

5800

Bandwidth, Hz

100

Temperature range, °C

-55 ~ +75

Input Voltage, VDC

±14.0 ~ ±16.0

Power consumption at ±15 VDC, W

0.4

Shock (operational)

100 g, 5 ms

Vibration (operational)

30 g, 10 ~ 2,000 Hz

Resource

10,000 hr

Dimension, mm

35 x 22 x 24

Weight, grams

35

 

     